Result charts
Create time-series charts of the building simulation: temperatures, energy balances as lines or monthly bars, heating/cooling loads, legend and export.
VICUS Buildings Page 3 of 4 in this chapter
Overview
Besides the false-color display, the results view shows the simulation results as time-series diagrams and data tables. Diagrams are stored in the project and redrawn with the current result files after every simulation run. They are based on the default building outputs (option Generate default building-related outputs on the Outputs page).
Access
Click Results in the left main toolbar, then Plots in the toolbar of the results view on the right (if the Districts workspace is active at the same time: Plots Buildings). The property area then shows the list of diagrams; the diagrams themselves appear in the plot matrix next to the 3D scene.
Diagram list
The Diagrams table lists all building diagrams of the project with the columns Type, Description, plot visibility and cache and data status. As with the false-color views, the status icons mean Up-to-date,
Reload (file available but not yet read; double-click reads the data) and
Missing (required result file not available). The Required output files table below names the result files of the highlighted diagram and their status.
Tools of the list:
Add diagram – opens the Create new diagram dialog (see below).
Edit diagram – opens the Diagram Options of the highlighted diagram (only with exactly one diagram highlighted).
Remove diagram – removes the highlighted diagrams.
- Make the selected plots visible / Hide the selected plots – shows or hides diagrams in the matrix without deleting them.
- Filter plots by name… – filters the list by type and description.
All changes to diagrams can be undone and are saved with the project.
Creating a diagram
In the Create new diagram dialog you choose the Diagram type, a Diagram description (proposed automatically, serves as a unique name; a diagram with the same name is overwritten after confirmation) and, under Object selection, the rooms:
- Current selection – only the rooms currently selected in the 3D scene. This option is preselected if rooms are selected when the dialog opens.
- All rooms (for heating/cooling loads All zones) – all rooms of the project.
The dialog shows how many lines the diagram will receive. So select the rooms in the scene or the navigation tree before creating the diagram if it should not contain all rooms.
Diagram types
| Diagram type | Content |
|---|---|
| Temperatures | One line per room with the operative temperature (default) or the air temperature, plus the Ambient temperature. Contains only the rooms chosen on creation; without a selection, all rooms. Switch between air and operative temperature in the diagram options (Show air temperatures / Show operative temperatures). |
| Energy balances | Heat flows of the chosen rooms as stacked areas over time: Equipment load, Lighting load, Person load, Cooling load, Heating load, Solar gains, Ventilation heat load, Convection through walls, Convection through windows; the Total thermal load is drawn on top as a dashed line. Gains are positive, losses (including the cooling load) negative. |
| Energy balances (integrals) | The same balance quantities as a bar chart with monthly columns (Monthly energy balances) or – with Show annual balances – as annual values (Annual energy balances). With Show total energy consumption (kWh) the bars show energies, otherwise mean powers. |
| Heating / cooling loads | Heating and cooling power per Aggregation level: Per zone, Per building or Total over all zones. Besides ideal heating/cooling it also contains the power of surface heating systems, if the project has any. |
For energy balances you also define in the diagram options which rooms are summed up (Entire building or Use currently selected zones) and whether heat flows through internal walls are ignored (Exclude internal walls when accumulating energy flows). Rooms hidden in the scene are not included in the balance.
Plot matrix
The diagrams are arranged in a matrix. By default Stack plots in a single column is enabled, so all diagrams are stacked one below the other; without the option, VICUS Buildings arranges them automatically in a grid. The whole matrix can be undocked into a free floating window (window title Result diagrams) with the button at the edge of the matrix, for instance for a second screen; closing the window docks it back.
Clicking into a diagram makes it the active diagram. The 3D scene is colored according to the active diagram: for the temperature diagram and for heating/cooling loads Per zone, each room gets the color of its line; for energy balances and summed heating/cooling loads, the contributing rooms are shown white. All other rooms, and rooms whose line is hidden, stay grey.
Working in the diagram:
- Dragging with the left mouse button zooms into an area; the right mouse button undoes the last zoom step, Ctrl + right mouse button resets the zoom; the middle mouse button pans. A zoom on the time axis is applied to all diagrams.
- Clicking a line selects the associated object (e.g. the room) in the scene, scrolls to it in the navigation tree and points the camera at the selection.
- When rooms are selected in the scene, the lines of the other rooms are dimmed in grey; lines of rooms hidden in the scene are not drawn.
The toolbar of each diagram offers:
– export the diagram as an image file (PNG, PDF, SVG, …).
– copy the diagram data to the clipboard as a table (paste directly into Excel).
- Toggle between diagram and table view.
- Undock the individual diagram into its own window.
- Hide/Close – hides the diagram.
Legend
Next to each diagram is a legend table with one row per line:
- Click on the color field – change the line color.
- Click on the light bulb icon – show or hide the line.
- Click on
– select the associated object in the scene (only for lines that belong to a room).
- Double-click on the name – show only this line; double-click again to show all lines.
The Filter lines by name… field hides legend rows and their lines whose name does not match. For diagrams with one line per room, the filtered-out rooms also stay grey in the scene while the diagram is active. Color and visibility of the lines are stored in the diagram.
Good to know
For assessing critical rooms, a temperature diagram with a few specifically selected rooms works better than one with all rooms: the lines remain distinguishable, and clicking a conspicuous line leads straight to the room in the scene. The Energy balances (integrals) bar chart shows at a glance which heat flows determine the heating and cooling demand over the year.